MET-959 Dual Input K/J-Type Thermometer
°C
°F
°K
Min/Max
Memory
Data
Hold
Average
Back
Light
Auto
Off
Low
Battery
1
CAL
Battery
The MET-959 brings increased accuracy and resolution to high-temperature
measurement, offering a 0.1°C resolution all the way up to 1000°C. In
addition, this instrument supports the use of both K or J-type probes.
Dual-input thermometer accepts 2 inputs with
individual measurements or as differential
measurements, T1 minus T2.
A sampling rate of 2.5 times per second.
Data hold freezes displayed values.
Min/max memory since power on or last reset.
Average function of the last 10 measured values.
Auto power off.
Low battery indication.
Impact-resistant ABS case with a 4 mm camera bush.
Temperature Range
K-Type
J-Type
1372°C
1100°C
x 1°C
x 1°C
1000°C
1000°C
0.1°C
Supplied with: 2 x 950 mm bead probes, soft carry case,
battery.
0.1°C
-200°C
View Product
-200°C
MET-960 4 Input K/J-Type Thermometer
°C
°F
°K
Min/Max
Memory
Data
Hold
Average
Back
Light
Auto
Off
Low
Battery
CAL
Battery
2
The MET-960 brings increased accuracy and resolution to
high-temperature measurement, offering a 0.1°C resolution all
the way up to 1000°C. In addition, this instrument supports
the use of both K or J-Type probes.
Supplied with: 2 x 950 mm bead probes, soft carry
case, battery.
Inputs / Type
Issued at
Additional Points
CAL-TK
1372°C
1100°C
x 1°C
1000°C
0.1°C
-200°C
x 1°C
1000°C
0.1°C
View Product
-200°C
CAL
1
MET-959
2
MET-960
Range (K-Type)
-200°C to 1372°C
-200°C to 1372°C
-20, 20, 50, 100, 200, 300, 400, 500 & 1000°C
Range (J-Type)
-200°C to 1100°C
-200°C to 1100°C
+£5.00 per point
From -160°C to 1260°C
£58.00
Certificate
CAL-TKSYS
Unit + 1 probe
Issued at
25, 50, 100 & 140°C
Additional Points
+£10.00 per point
From -20°C to 140°C
Price
J-Type
1 / Unit only
Price
Inputs / Type
Temperature Range
K-Type
Technical Specifications
Calibration Options
Certificate
Temperature
Quad-input thermometer accepts 4 inputs with
individual measurements or as differential
measurements, T1 minus T2 or T3 minus T4.
A sampling rate of 2.5 times per second.
Data hold freezes displayed values.
Min/max memory since power on or last reset.
Average function of the last 10 measured values.
Auto power off.
Low battery indication.
Impact-resistant ABS case with a 4 mm camera
bush.
No. of Inputs
2
4
Resolution
0.1°C < 1000°C
1°C > 1000°C
0.1°C < 1000°C
1°C > 1000°C
Accuracy
CAL
Sampling Rate
2.5 times per second
N/A
Dimensions
185 x 66 x 33 mm (Unit)
185 x 66 x 33 mm (Unit)
Display Size
55 mm dual-display
N/A
Weight
245 g
245 g
Power
1 x 9V PP3 alkaline battery
(LR-61)
1 x 9V PP3 alkaline battery
(LR-61)
Price
£62.95
£68.25
£75.00
sales@atp-instruments.co.uk
±(0.15°C +1°C) (0°C to 1000°C) ±(0.15°C +1°C) (0°C to 1000°C)
±(0.5% +2°C) (Others)
±(0.5% +2°C) (Others)
01530 566800
www.atp-instrumentation.co.uk
15